It is used for storage of expansion water, make-up water and gas separation in central heating and refrigeration system. ◆ it can automatically drain or top up the system with long expansion. The multifunctional control unit is equipped with micro electronic controller to realize automatic control and operation. ◆ this simple control unit can be operated by one hand, and the operation of the expansion system can be displayed on the interface intuitively and clearly. The control unit can be used remotely (up to 500m), so that you can observe the operation of the system at any time in the office. ◆ bubbles with a diameter of more than 18 microns (micrometer) can be removed from the system by using the Bauer ring with flamco patent. The large adsorption surface of Bauer ring means that all kinds of bubbles in the system can be removed. More details can be found in an independent research report from the Technical University of ddlft in the Netherlands, which can be obtained from flamco. |
|
◆Ral (3002) epoxy powder coating。
◆Maximum operating pressure:6bar
◆Maximum temperature load of diaphragm(DIN4807/3):70℃
◆Maximum operating temperature (Design):120℃
Single pump control unit of flamcomat pump type constant pressure unit
type | Maximum working pressure | Dimension (mm) Length × width × height | take over | weight | Power of each pump kw | Rated full load current | flow | lift | Product code | |||
bar | system | Replenishment | kg | Alift | m | |||||||
Mm | 3.0 | 350×250×550 | G1'' | RP 3/4'' | R 1/2'' | 12 | 0.1 | 0.5 | 0.18 | 30 | 1 | 17880 |
M 0 | 3.5 | 440×330×890 | G1 1/4'' | RP 1'' | R 1/2'' | 15 | 0.37 | 2.1 | 0.48-1.98 | 33-5 | 17786 | |
M 01 | 3.5 | 17 | t0.55 | 2.77 | 0.3-2.4 | 40-6.5 | 17787 | |||||
M 02 | 3.5 | 17 | 0.55 | 2.77 | 0.3-2.4 | 40-6.5 | 17789 | |||||
M 10 | 5.0 | 460×380×890 | G1 1/4'' | potRP 1'' | R 1/2'' | 20 | 0.82 | 5.1 | 5 | 56 | 17780 | |
M 20 | 5.0 | 23 | 1.1 | 7.2 | 8 | 57 | 17781 | |||||
M 60 | 8.5 | 410×410×915 | G1 1/2'' | RP1 1/4'' | R 1/2'' | 40 | 1.1 | 7.4 | 3 | 69.7 | 17784 | |
M 80 | 10.7 | 600×550×915 | 50 | 1.5 | 3.45 | 4 | 131-52 | 17882 | ||||
M 100 | 14.4 | 600×550×990 | 54 | 2.2 | 5.03 | 4 | 150-59 | 17884 | ||||
M 130 | 14.4 | 600×550×1190 | 62 | 3.05 | 6.01 | 4 | 20t6-81 | 17886 |
Dual pump control unit of flamcomat pump type constant pressure unit
type | Maximum working pressure bar | Dimension (mm) Length × width × height pot | take over | weight kg | Power of each pump kw | Rated full load current | flow m3/h | lift m | Product code | |||
pot | system | Replenishment | ||||||||||
Dm | 3.0 | 350×250×550 | G1'' | RP 3/4'' | R 1/2'' | 14 | 0.1 | 0.5 | 0.18 | 30 | 1 | 17881 |
D 02 | 3.5 | 590t×500×890 | G1 1/2'' | RP1 1/4'' | R 1/2'' | 34 | 0.55 | 2.77 | 0.3-2.4 | 40-6.5 | ft17788 | |
D 10 | 5.0 | 34 | 0.85 | 5.1 | 5 | 56 | 17782 | |||||
D 20 | 5.0 | 40 | 1.1 | 7.2 | 8 | 57 | 17783 | |||||
D 60 | 8.5 | 560×410×915 | G1 1/2'' | RP1 1/4'' | R 1/2'' | 75 | 1.1 | 7.4 | 3 | 69.7 | 17785 | |
D 80 | 10.7 | 700×550×915 | 90 | 1.5 | 3.45 | 4 | 131-59 | 17883 | ||||
D 100 | 14.4 | 700×550×990 | 95 | 2.2 | 5.03 | 4 | 150-59 | 17885 | ||||
D 130 | 14.4 | 700×550×1190 | 115 | 3.05 | 6.01 | 4 | 206-81 | 17887 |
For heating and cooling systems
◆ multifunctional products can provide all the important requirements of closed heating and cooling system, such as automatic constant pressure control, degassing and water supplement.
◆ non pressure tank without control unit.
◆ the volume control can be maintained automatically in the process of heating and cooling cycle, and the water can be replenished automatically.
◆ all air can be removed. Even if the system is in a balanced state, the unique strong degassing mode can provide continuous degassing according to the demand.
◆ the patented pall ring technology is used for low-pressure degassing, which can prolong the service life of the circulation system and improve the efficiency.
◆ design pressure: pn6
◆ according to Pressure Equipment Directive 97 / 23 / EG
Flamcomat GB water pump type constant pressure unit main tank
type | volume | size | System connection | weight(kg) | |||
φ(mm) | high(mm) | Product code | |||||
(M) | |||||||
GB 150 | 150 | 550 | 1350 | G1 1/2'' | 55 | 1 | 17710 |
GB 200 | 200 | 550 | 1530 | 70 | 17711 | ||
GB 300 | 300 | 550 | 2030 | 90 | 17712 | ||
GB 400 | 40 | 750 | 1535 | 130 | 17713 | ||
GB 600 | 600 | 750 | 1955 | 160 | 17714 | ||
GB 500 | 500 | 750 | 1760 | 151 | 17729 | ||
GB 800 | 800 | 750 | 2355 | 195 | 17715 | ||
GB 1000 | 1000 | 1000 | 1915 | 261 | 17726 | ||
GB 1000 | 1000 | 750 | 2855 | 226 | 17716 | ||
GB 1200 | 1200 | 1000 | 2210 | 290 | 17717 | ||
GB 1600 | 1600 | 1000 | 2710 | 345 | 17718 | ||
GB 2000 | 2000 | 1200 | 2440 | 430 | 17719 | ||
GB 2800 | 280 | 1200 | 3040 | 515 | 17720 | ||
GB 3500 | 3500 | 1200 | 3840 | 625 | 17721 | ||
GB 5000 | 5000 | 1500 | 3570 | 1240 | 17722 | ||
GB 6500 | 6500 | 1800 | 3500 | 1710 | 17723 | ||
GB 8000 | 8000 | 1900 | 3650 | 1830 | 17724 | ||
GB 10000 | 10000 | 2000 | 4050 | 2025 | 17725 | ||
Flamcomat BB水泵式定压机组主罐
type | volume(升) | size | System connection | weight | |||
φ | high | Product code | |||||
(升) | (mm) | (M) | |||||
BB 150 | 150size | 550 | 1350 | G1 1/2'' | 55 | 1 | 17760 |
BB 200 | 200 | 550 | 1530 | 70 | 17761 | ||
BB 300 | 300 | 550 | 2030 | 90 | 17762 | ||
BB 400 | 40 | 750 | 1535 | 130 | 17763 | ||
BB 600 | 600 | 750 | 1760 | 150 | 17779 | ||
BB 500 | 500 | 750 | 1955 | 160 | 17764 | ||
BB 800 | 800 | 750 | 2355 | 195 | 17765 | ||
BB 1000 | 1000 | 750 | 2855 | 226 | 17766 | ||
BB 1000 | 1000 | 1000 | 1915 | 260 | 17776 | ||
BB 1200 | 1200 | 1000 | 2210 | 290 | 17767 | ||
BB 1600 | 1600 | 1000 | 2710 | 345 | 17768 | ||
BB 2000 | 2000 | 1200 | 2440 | 430 | 17769 | ||
BB 2800 | 280 | 1200 | 3040 | 515 | 17770 | ||
BB 3500 | 3500 | 1200 | 3840 | 625 | 17771 | ||
BB 5000 | 5000 | 1500 | 3570 | 1240 | 17772 | ||
BB 6500 | 6500 | 1800 | 3500 | 1710 | 17773 | ||
BB 8000 | 8000 | 1900 | 3650 | 1830 | 17774 | ||
BB 10000 | 10000 | 2000 | 4050 | 2025 | 17775 |
Flamcomat水泵式单—双罐自动定压装置安装举例
| |
单罐 | 双罐 |
Selection description of flamcomat pump type automatic constant pressure system
Model Description:
It is composed of basic tank body, automatic make-up water system (including high-efficiency make-up water pump), programmable automatic control unit (including RS485 communication data interface) and relevant connecting pipes: flexcon FB + M-0 (M01, M-1, m-2, d-o, D-1, D-3 < water pump power 0.75kw/220v >, M-3, D-3 < Water pump power 1.1kw/220v >), and supporting connecting hose.
M-single pump series d-double pump series
Model selection curve:
Tank volume VFG (L) = 0.3450 heating power (kw)
The system with net height higher than 50m can be customized
Shanghai Hangcheng constant pressure device