performance parameter




Single flow: 300-2800m3 / h, larger flow can be paralleled by multiple single machines.


Minimum working pressure: 0.2MPa


Maximum working pressure: 1.6 MPa, 2.5 MPa, 4.0 MPa


Maximum working temperature: 70 ℃


Filter accuracy: 100-3500 μ M


Control mode: pressure difference, time and manual


Cleaning method: electric brush


Cleaning time: 30-60 seconds


Speed of cleaning mechanism: 14r.p.m


Cleaning pressure loss: 0.01 MPa


Control voltage: AC 220V


Rated operating voltage: three-phase 200V / 380V 50Hz

 

 

 

 

Technical parameters and Boundary dimensions

model

Diameter of inlet and outlet (mm)

Flow (m3 / h)

Filter area




(C m2)


Blowdown valve (DN)

Primary cleaning water volume (L)

Motor power (kw)

height(kg)

structure size


¢D

H

H1

H2

H2*

L1

L2

L


mm

mm

mm

mm

mm

mm

mm

mm


FTMTL8

200

300

6000

50

200

0.37

228

426

670

1105

1335

2000

390

360

1000

FTMTL10

250

450

6000

50

200

0.37

248

426

670

1105

1335

2000

390

360

1000

FTMTL12

300

650

6000

50

200

0.37

257

426

670

1105

1335

2000

390

360

1000

FTMTL14

350

900

12000

80

500

0.55

530

630

900

1572

1800

2800

550

465

1200

FTMTL16

400

1200

12000

80

500

0.55

564

630

900

1572

1800

2800

550

465

1200

FTMTL18

450

1500

18000

80

500

0.75

950

924

985

1728

1970

3000

660

662

1600

FTMTL20

500

2000

18000

80

500

0.75

1000

924

985

1728

1970

3000

660

662

1600

FTMTL24

600

2800

18000

80

500

0.75

1050

924

985

1728

1970

3000

660

662

1600

Note: H2 * is the minimum size required to open the filter






Single flow: 3200-9300m3 / h, larger flow can be paralleled by multiple single machines.


Minimum working pressure: 0.2MPa


Maximum working pressure: 1.0 MPa, 1.6 MPa


Maximum working temperature: 70 ℃


Filtration accuracy: 500-3500 μ M


Control mode: pressure difference, time and manual


Cleaning method: electric brush


Cleaning time: 30-60 seconds


Speed of cleaning mechanism: 14r.p.m


Cleaning pressure loss: 0.01 MPa


Control voltage: AC 220V


Rated operating voltage: three-phase 200V / 380V 50Hz








Technical parameters and Boundary dimensions

model

Diameter of inlet and outlet (mm)

Flow (m3 / h)

Filter area




(C m2)


Blowdown valve (DN)

Primary cleaning water volume (L)

Motor power (kw)

height(kg)

structure size


¢D

H

H1

H1*

H2

E

¢D1

B

C

C1

C1


mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm


FTMT28

700

3200

24000

65

750

1.1

2050

1428

1450

2980

4300

350

1800

1680

250

250

890

30

FTMT32

800

4200

30000

65

750

1.5

2960

1628

1550

3210

4600

350

2000

1920

280

280

1020

34

FTMT36

900

5300

39000

80

750

1.5

3800

1832

1750

3560

5200

400

2200

2140

300

300

1130

34

FTMT40

1000

6500

47000

80

1000

2.2

4720

2032

1850

3830

5600

400

2500

2340

300

300

1230

34

FTMT48

1200

9300

68000

80

1000

2.2

7250

2440

2150

4500

6600

400

3000

2760

360

360

1460

34

Note: H1 * is the minimum size required to open the filter