Summary




Qpg-ii electric automatic flushing blowdown filter can set the blowdown resistance value arbitrarily according to the pressure difference between the front and the back of the filter (i.e. resistance). It is a kind of filter developed on the basis of TFP automatic flushing blowdown filter, which relies on automatic components and electric actuators to complete the filtering, cleaning and blowdown functions automatically. Qpg-ii electric automatic flushing blowdown filter has the advantages of full automation, small volume, large filtering capacity and convenient operation. It has the functions of automatic filtration and blowdown and automatic backwash. The cleaning and blowdown are completed together in the process of online filtration without stopping the water flow. It can remove all kinds of impurities in the medium, and it can be used for the pretreatment of raw water, industrial water, domestic water and recycling of useful substances in industrial wastewater.








Structure description




The filter consists of shell, stainless steel filter screen, impurity collection section, electric impurity discharge outlet, electric water flow steering valve, detection mechanism, actuator and control box. According to the different installation type and water flow direction, it can be divided into straight through type and right angle type.












Model description

 

technical parameter

flowSpecification of filter screenworking pressuretemperature rangeControl box power supply
15m3/h~7900m3/h
Control box power supplyDN40~80 1.6mm DN100~600 2.0mm

DN700~1000 3.0mm(According to the user's requirements)
DN<600 1.6MPa DN>600 1.0MPa
mediumWater and liquid
≤180℃
Electric actuator power supply380VAC,50HZ
220VAC,50HZ;380VAC,50HZ

Boundary dimension

型号ABCDEFGDNDN1Steering valve actuatorDrain valve actuator
ModelpowerModelpower
QPG-II-150(B)64522048019550565086015050LQ20-160WD971-F16W
QPG-II-200(B)79526054025858075098020065
QPG-II-250(B)825310590302655860115025080
QPG-II-300(B)8503503503507501000131030010025W
QPG-II-350(B)9104107304008751180151535012560W
QPG-II-400(B)930470780435100013501730400150LQ40-190W
QPG-II-450(B)985510830495112515001900450
QPG-II-500(B)1025550960545125016802080500
QPG-II-600(B)10706501050645150020002490600200180W90W
QPG-II-700(B)11406801150780160021502680700LQ80-1
QPG-II-800(B)12207001300900175023002880800
QPG-II-900(B)130080014501100185024803150900
QPG-II-1000(B)1400900161011502000267533701000250180W

QPG-A型直通式电动自动排污过滤器

型号ABCDLDNDN1Steering valve actuatorDrain valve actuator
ModepowerModelpower
QPG-II-150(A)48519548064567515050LQ20-160WD971-F16W
QPG-II-200(A)49025854079573520065
QPG-II-250(A)58530259082587525080
QPG-II-300(A)698350650850105030010025W
QPG-II-350(A)785400730910120035012560W
QPG-II-400(A)9404357809301400400150LQ40-190W
QPG-II-450(A)10354958309851550450
QPG-II-500(A)114054596010251700500
QPG-II-600(A)1315645105010702000600200180W90W
QPG-II-700(A)1580780115011402280700LQ80-1
QPG-II-800(A)1720900130012202500800
QPG-II-900(A)20001000145013002800900
QPG-II-1000(A)227011501610140031201000250180W

 

 

 

working principle




1. Regular flushing and blowdown


Regular cleaning and blowdown can be set for 2-24 hours. When the timing time is up, the electric actuator will open the blowdown valve, and the filter will blow down for 10-30 seconds. Then the electric actuator will rotate the steering valve 90 ° to block the filter cartridge position, change the water flow path, and clean up and blow down for 10-30 seconds. Reset the steering valve, continue to drain for 3 to 5 seconds, and then close the drain outlet.


2. Differential pressure control blowdown


The action value of the differential pressure controller can be set as 0.03-0.07mpa. When the differential pressure before and after the filter reaches the action setting value of the differential pressure controller, the differential pressure controller will act. The filter drain valve will be opened, and it will end in 10-30 seconds. The steering valve will be reset, and the blowdown will continue for 3-5 seconds, and the drain valve will be closed.


3. Manual push control


The button on the control box can directly control the cleaning and blowdown.








Performance and characteristics




1. Qpg-ii electric automatic flushing blowdown filter has the advantages of convenient operation and management, high filtering speed, simple and reliable flushing and strong backwashing ability.


2. The flushing blowdown can work normally under the full flow, which not only maintains the high flow rate of the system, but also has a very low pressure drop (less than 0.05-0.1m water column), avoiding the surface stains caused by the low flow rate.


3. Save investment and operation cost. In the installation process, there is no need to set bypass pipeline, which reduces the investment and installation cost of three bypass valves. It is directly installed on the pipe network without any support structure, saving space. No need to dismantle the sewage, reducing the labor intensity, avoiding the dismantling sewage in the process of debugging and maintenance, saving labor, labor and time.


4. Manual timing or differential pressure control mode can automatically clean the filter blowdown to ensure the efficient use of the filter.


5. It can be installed horizontally and vertically with the same effect. The drain outlet can be located according to the user's needs.


6. The resistance of the filter at the rated flow rate is 0.05-0.1m water column.


7. The filter screen cylinder is fixed and connected to the cylinder as a whole, with good rigidity, strength, no wearing parts and long service life.


8. Specifications of filter screen: 10 mesh / mouth inch, 14 mesh / mouth inch, 20 mesh / mouth inch. It can also be customized according to user requirements to meet the requirements of poor water quality treatment.


9、 The control box is equipped with filter working state, cleaning state, fault state indication and corresponding signal output.


10. The flushing and backwashing time can be adjusted first, and the blowdown volume is less than 10% of the normal working flow.


11. Refer to TFP type automatic flushing blowdown filter for installation.


12. The control box is installed near the control room or filter.